HistoricBridges.org Menu: HistoricBridges.org Menu:



BridgeSeek

Nearby Bridges in NBI 2021: 17


MITCHELL STREET over NS RAILROAD (Route: 9161)
Num:12153500x
Open: no restriction [A]
Built: 2012, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.1 Miles (0.1 Kilometers)

Bridge Type
Main Span(s): Steel continuous [4] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 168.2 m = 551.9 ft
Main Spans: 5 at 49.4 m = 162.1 ft
Approach Spans: 0
Skew: 99
Width, Roadway: 15 m = 49.2 ft (3 Lanes) and Out-To-Out: 23 m = 75.5 ft for a 12.8 m = 42.0 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
IN SW ATLANTA
Condition
Deck: Good [7]
Superstructure: Very Good [8]
Substructure: Good [7]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 42.6 metric ton = 46.9 tons (Load Factor(LF) [1])
Inventory: 25.4 metric ton = 27.9 tons (Load Factor(LF) [1])
Appraisal
Structural: Equal to present minimum criteria [6]
Deck Geometry: Equal to present minimum criteria [6]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: January 2021 [0121] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 5410 (2011) and Trucks: 1%
Future ADT: 8115 (In 2032 )
RICHARD RUSSELL over PARKING LOT NS RR (Route: 3470)
Num:12151720x
Open: no restriction [A]
Built: 1982, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.1 Miles (0.2 Kilometers)

Bridge Type
Main Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 127.4 m = 418.0 ft
Main Spans: 6 at 25.3 m = 83.0 ft
Approach Spans: 0
Skew: 99
Width, Roadway: 13.4 m = 44.0 ft (2 Lanes) and Out-To-Out: 18.5 m = 60.7 ft for a 13.4 m = 44.0 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
IN ATLANTA
Condition
Deck: Good [7]
Superstructure: Satisfactory [6]
Substructure: Satisfactory [6]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 46.3 metric ton = 50.9 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Equal to present minimum criteria [6]
Deck Geometry: Superior to present desirable criteria [9]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: March 2020 [0320] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 1940 (2011) and Trucks: 1%
Future ADT: 2910 (In 2031 )
SR 14: PETERS STRE over NS RAILROAD (Route: 14)
Num:12100490x
Open: would be posted or closed except for temporary shoring [D]
Built: 1935, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.1 Miles (0.2 Kilometers)

Bridge Type
Main Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Approach Span(s): Concrete [1] Girder and floorbeam system [03]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 273.5 m = 897.4 ft
Main Spans: 6 at 36.6 m = 120.1 ft
Approach Spans: 20
Skew: 99
Width, Roadway: 15.4 m = 50.5 ft (4 Lanes) and Out-To-Out: 20.3 m = 66.6 ft for a 15.2 m = 49.9 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by State Highway Agency [01], DOT District: 7
IN WEST ATLANTA
Condition
Deck: Satisfactory [6]
Superstructure: Good [7]
Substructure: Good [7]
Loading
Design: M 13.5 / H 15 [2]
Operating: 27.2 metric ton = 29.9 tons (Allowable Stress(AS) [2])
Inventory: 17.2 metric ton = 18.9 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Meets minimum tolerable limits to be left in place as is [4]
Deck Geometry: Meets minimum tolerable limits to be left in place as is [4]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: April 2020 [0420] and Frequency: 24
Future Work
Work Needed: Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 5350 (2011) and Trucks: 1%
Future ADT: 8025 (In 2031 )
M.L.K. JR. DRIVE over NS RR-CS 3435 MANGUM (Route: 9134)
Num:12103910x
Open: no restriction [A]
Built: 1961, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.2 Miles (0.2 Kilometers)

Bridge Type
Main Span(s): Steel continuous [4] Stringer/Multi-beam or girder [02]
Approach Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 504.7 m = 1655.9 ft
Main Spans: 17 at 62.5 m = 205.1 ft
Approach Spans: 0
Skew: 99
Width, Roadway: 17.2 m = 56.4 ft (5 Lanes) and Out-To-Out: 22.6 m = 74.2 ft for a 21.9 m = 71.9 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
IN ATLANTA
Condition
Deck: Fair [5]
Superstructure: Good [7]
Substructure: Satisfactory [6]
Loading
Design: MS 18 / HS 20 [5]
Operating: 55.3 metric ton = 60.8 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Equal to present minimum criteria [6]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: March 2020 [0320] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 9920 (2011) and Trucks: 1%
Future ADT: 14880 (In 2031 )
M.L.K. JR. DRIVE over PARKING LOT & RICH'S (Route: 9134)
Num:12152390x
Open: no restriction [A]
Built: 1996, Reconstructed: 2018
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.2 Miles (0.3 Kilometers)

Bridge Type
Main Span(s): Concrete continuous [2] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 103 m = 337.9 ft
Main Spans: 4 at 25.6 m = 84.0 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 11.7 m = 38.4 ft (2 Lanes) and Out-To-Out: 27.7 m = 90.9 ft for a 16.5 m = 54.1 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
AT RICH'S DOWNTOWN
Condition
Deck: Good [7]
Superstructure: Very Good [8]
Substructure: Satisfactory [6]
Loading
Design:
Operating: 56.2 metric ton = 61.8 tons (Load Factor(LF) [1])
Inventory: 19.1 metric ton = 21.0 tons (Load Factor(LF) [1])
Appraisal
Structural: Meets minimum tolerable limits to be left in place as is [4]
Deck Geometry: Better than present minimum criteria [7]
Road Alignment: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: January 2021 [0121] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 5840 (2011) and Trucks: 1%
Future ADT: 8760 (In 2031 )
CEN OLYMPIC PARK D over M9161 MITCHELL-N SOU RR (Route: 9073)
Num:12103590x
Open: no restriction [A]
Built: 1961, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.3 Miles (0.4 Kilometers)

Bridge Type
Main Span(s): Steel continuous [4] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Bituminous [6]
Bridge Dimensions
Length: 683.1 m = 2241.3 ft
Main Spans: 30 at 48.8 m = 160.1 ft
Approach Spans: 0
Skew: 99
Width, Roadway: 17.1 m = 56.1 ft (5 Lanes) and Out-To-Out: 22.6 m = 74.2 ft for a 21.9 m = 71.9 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
IN ATLANTA
Condition
Deck: Fair [5]
Superstructure: Satisfactory [6]
Substructure: Fair [5]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 46.3 metric ton = 50.9 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: March 2020 [0320] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.3 km = 0.2 mi
Traffic
ADT: 4280 (2011) and Trucks: 1%
Future ADT: 6420 (In 2031 )
TED TURNER DRIVE over ALABAMA ST/CSX RR (Route: 9073)
Num:12100100x
Posted for load [P]
Built: 1997, Reconstructed: 2020
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.3 Miles (0.5 Kilometers)

Bridge Type
Main Span(s): Steel continuous [4] Stringer/Multi-beam or girder [02]
Approach Span(s): Prestressed concrete [5] Stringer/Multi-beam or girder [02]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 468.2 m = 1536.2 ft
Main Spans: 2 at 65.5 m = 214.9 ft
Approach Spans: 17
Skew: 0
Width, Roadway: 12.2 m = 40.0 ft (4 Lanes) and Out-To-Out: 18.2 m = 59.7 ft for a 12.2 m = 40.0 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
DOWNTOWN ATLANTA
Condition
Deck: Good [7]
Superstructure: Very Good [8]
Substructure: Good [7]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 25.4 metric ton = 27.9 tons (Allowable Stress(AS) [2])
Inventory: 11.8 metric ton = 13.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Basically intolerable requiring high priority of replacement [2]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: January 2021 [0121] and Frequency: 24
Future Work
Work Needed: Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 17350 (2018) and Trucks: 1%
Future ADT: 24615 (In 2031 )
WHITEHALL STREET over M-9073 SPRING STREET (Route: 9124)
Num:12100090x
Open: no restriction [A]
Built: 1963, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.3 Miles (0.6 Kilometers)

Bridge Type
Main Span(s): Steel continuous [4] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 65.5 m = 214.9 ft
Main Spans: 4 at 19.2 m = 63.0 ft
Approach Spans: 0
Skew: 31
Width, Roadway: 14.6 m = 47.9 ft (4 Lanes) and Out-To-Out: 20.3 m = 66.6 ft for a 14.6 m = 47.9 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
IN ATLANTA
Condition
Deck: Satisfactory [6]
Superstructure: Satisfactory [6]
Substructure: Satisfactory [6]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 46.3 metric ton = 50.9 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Equal to present minimum criteria [6]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: July 2020 [0720] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 7740 (2011) and Trucks: 1%
Future ADT: 11610 (In 2031 )
A. YOUNG INTL BLVD over MANGUM ST SW (Route: 2001)
Num:12104740x
Open: no restriction [A]
Built: 1974, Reconstructed: 1993
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.4 Miles (0.6 Kilometers)

Bridge Type
Main Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 880.9 m = 2890.2 ft
Main Spans: 30 at 40.8 m = 133.9 ft
Approach Spans: 0
Skew: 99
Width, Roadway: 16.5 m = 54.1 ft (4 Lanes) and Out-To-Out: 25.6 m = 84.0 ft for a 17.1 m = 56.1 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
IN ATLANTA
Condition
Deck: Satisfactory [6]
Superstructure: Very Good [8]
Substructure: Good [7]
Loading
Design: MS 18 / HS 20 [5]
Operating: 46.3 metric ton = 50.9 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Better than present minimum criteria [7]
Deck Geometry: Meets minimum tolerable limits to be left in place as is [4]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: October 2020 [1020] and Frequency: 24
Future Work
Work Needed: Widening of existing bridge with deck rehabilitation or replacement. [34]
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 6620 (2011) and Trucks: 1%
Future ADT: 9930 (In 2031 )
FORSYTH STREET over CSX RR & PARKING LOT (Route: 2038)
Num:12152700x
Open: no restriction [A]
Built: 1979, Reconstructed: 1996
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.4 Miles (0.6 Kilometers)

Bridge Type
Main Span(s): Prestressed concrete [5] Stringer/Multi-beam or girder [02]
Approach Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Bituminous [6]
Bridge Dimensions
Length: 143 m = 469.2 ft
Main Spans: 4 at 26.8 m = 87.9 ft
Approach Spans: 3
Skew: 0
Width, Roadway: 13.4 m = 44.0 ft (4 Lanes) and Out-To-Out: 19.2 m = 63.0 ft for a 13.4 m = 44.0 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
IN ATLANTA
Condition
Deck: Good [7]
Superstructure: Good [7]
Substructure: Good [7]
Loading
Design: MS 18 / HS 20 [5]
Operating: 55.3 metric ton = 60.8 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Better than present minimum criteria [7]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Better than present minimum criteria [7]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: October 2020 [1020] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 12880 (2011) and Trucks: 1%
Future ADT: 19320 (In 2031 )
SERVICE RD PARKING over M-9315 INTERNATIONAL BLD (Route: 20065)
Num:12104730x
Open: no restriction [A]
Built: 1974, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.4 Miles (0.6 Kilometers)

Bridge Type
Main Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 58.5 m = 191.9 ft
Main Spans: 4 at 17.1 m = 56.1 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 4.9 m = 16.1 ft (1 Lanes) and Out-To-Out: 6.1 m = 20.0 ft for a 4.9 m = 16.1 ft approaching roadway.
Vertical Clearance: 4.92 m = 16.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
IN ATLANTA
Condition
Deck: Good [7]
Superstructure: Satisfactory [6]
Substructure: Good [7]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 46.3 metric ton = 50.9 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Equal to present minimum criteria [6]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: October 2020 [1020] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 6620 (2011) and Trucks: 1%
Future ADT: 9930 (In 2031 )
PEACHTREE STREET over CSX RAILROAD (Route: 9158)
Num:12153200x
Open: no restriction [A]
Built: 2007, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.4 Miles (0.7 Kilometers)

Bridge Type
Main Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 84.4 m = 276.9 ft
Main Spans: 5 at 21.9 m = 71.9 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 11.4 m = 37.4 ft (4 Lanes) and Out-To-Out: 19.5 m = 64.0 ft for a 12.2 m = 40.0 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
IN CITY OF ATLANTA
Condition
Deck: Good [7]
Superstructure: Very Good [8]
Substructure: Very Good [8]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 55.3 metric ton = 60.8 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Equal to present desirable criteria [8]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Equal to present minimum criteria [6]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: June 2020 [0620] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 12620 (2005) and Trucks: 1%
Future ADT: 189300 (In 2030 )
I-20- AND 2 RAMPS over M-9160 WINDSOR STREET (Route: 20)
Num:12101810x
Open: no restriction [A]
Built: 1962, Reconstructed: 1987
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.4 Miles (0.7 Kilometers)

Bridge Type
Main Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 67.7 m = 222.1 ft
Main Spans: 4 at 17.7 m = 58.1 ft
Approach Spans: 0
Skew: 22
Width, Roadway: 58.1 m = 190.6 ft (10 Lanes) and Out-To-Out: 60 m = 196.9 ft for a 46.6 m = 152.9 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by State Highway Agency [01], DOT District: 7
IN ATLANTA
Condition
Deck: Good [7]
Superstructure: Good [7]
Substructure: Good [7]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 33.6 metric ton = 37.0 tons (Load Factor(LF) [1])
Inventory: 20 metric ton = 22.0 tons (Load Factor(LF) [1])
Appraisal
Structural: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck Geometry: Superior to present desirable criteria [9]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: June 1999 [699] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.5 km = 0.3 mi
Traffic
ADT: 142590 (2012) and Trucks: 1%
Future ADT: 213885 (In 2032 )
I-75 RMP TO I-20WB over M9164 & RMP- M9166 & RMP (Route: 75)
Num:12107060x
Open: no restriction [A]
Built: 1989, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.4 Miles (0.7 Kilometers)

Bridge Type
Main Span(s): Prestressed concrete continuous [6] Box Beam or girders - Single or Spread [06]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 158.5 m = 520.0 ft
Main Spans: 3 at 57.9 m = 190.0 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 13.1 m = 43.0 ft (1 Lanes) and Out-To-Out: 14.1 m = 46.3 ft for a 9.8 m = 32.2 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by State Highway Agency [01], DOT District: 7
I-75 & I-20 INTERCHANGE
Condition
Deck: Good [7]
Superstructure: Good [7]
Substructure: Good [7]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 55.3 metric ton = 60.8 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Better than present minimum criteria [7]
Deck Geometry: Superior to present desirable criteria [9]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: October 1999 [1099] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.3 km = 0.2 mi
Traffic
ADT: 30950 (2012) and Trucks: 1%
Future ADT: 46425 (In 2032 )
I-20 RMP TO I-75 over I-20R(WINDSOR ST)TO I20E (Route: 20)
Num:12107070x
Open: no restriction [A]
Built: 1989, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.5 Miles (0.7 Kilometers)

Bridge Type
Main Span(s): Prestressed concrete [5] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface:
Bridge Dimensions
Length: 14 m = 45.9 ft
Main Spans: 1 at 14 m = 45.9 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 14.4 m = 47.2 ft (3 Lanes) and Out-To-Out: 15.4 m = 50.5 ft for a 12.2 m = 40.0 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by State Highway Agency [01], DOT District: 7
IN ATLANTA
Condition
Deck: Good [7]
Superstructure: Very Good [8]
Substructure: Good [7]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 55.3 metric ton = 60.8 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Better than present minimum criteria [7]
Deck Geometry: Better than present minimum criteria [7]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: July 1999 [799] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.3 km = 0.2 mi
Traffic
ADT: 31580 (2012) and Trucks: 1%
Future ADT: 47370 (In 2032 )
PRYOR STREET over CSX RR (340311N) (Route: 2044)
Num:12151750x
Open: no restriction [A]
Built: 1929, Reconstructed: N/A [0000]
Historic: Bridge is eligible for the NRHP. [2]

Google Streetview (If Available)

Rough Distance: 0.5 Miles (0.8 Kilometers)

Bridge Type
Main Span(s): Steel [3] Girder and floorbeam system [03]
Approach Span(s): Concrete continuous [2] Tee beam [04]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Bituminous [6]
Bridge Dimensions
Length: 221.3 m = 726.1 ft
Main Spans: 5 at 16.5 m = 54.1 ft
Approach Spans: 18
Skew: 0
Width, Roadway: 13.6 m = 44.6 ft (4 Lanes) and Out-To-Out: 19.4 m = 63.7 ft for a 17.1 m = 56.1 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by City or Municipal Highway Agency [04], DOT District: 7
IN ATLANTA
Condition
Deck: Satisfactory [6]
Superstructure: Satisfactory [6]
Substructure: Satisfactory [6]
Loading
Design: M 13.5 / H 15 [2]
Operating: 47.2 metric ton = 51.9 tons (Load Factor(LF) [1])
Inventory: 21.8 metric ton = 24.0 tons (Load Factor(LF) [1])
Appraisal
Structural: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Better than present minimum criteria [7]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: April 2020 [0420] and Frequency: 24
Future Work
Work Needed: Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 1940 (2011) and Trucks: 1%
Future ADT: 2910 (In 2031 )
I-20R WB TO WINDSO over I-75-3I-75RMP-3I-20RMP-3 (Route: 20)
Num:12106580x
Open: no restriction [A]
Built: 1988, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.5 Miles (0.8 Kilometers)

Bridge Type
Main Span(s): Prestressed concrete continuous [6] Box Beam or girders - Single or Spread [06]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Epoxy Overlay [5]
Bridge Dimensions
Length: 640.1 m = 2100.2 ft
Main Spans: 11 at 73.2 m = 240.2 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 9.1 m = 29.9 ft (1 Lanes) and Out-To-Out: 10.1 m = 33.1 ft for a 9.4 m = 30.8 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Atlanta [04000]: Fulton County [121], Georgia [13]
Owned by State Highway Agency [01], DOT District: 7
I-20 & I-75 INTERCHANGE
Condition
Deck: Good [7]
Superstructure: Good [7]
Substructure: Good [7]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 55.3 metric ton = 60.8 tons (Allowable Stress(AS) [2])
Inventory: 32.7 metric ton = 36.0 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Better than present minimum criteria [7]
Deck Geometry: Superior to present desirable criteria [9]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: January 2020 [0120] and Frequency: 24
Future Work
Work Needed:
Bridge Detour: 0.5 km = 0.3 mi
Traffic
ADT: 4990 (2012) and Trucks: 1%
Future ADT: 7485 (In 2032 )

Special Bridge Conditions Legend: R - Former location of relocated bridge. ! - At risk for demolition or destruction. X - Confirmed demolished or collapsed. S  - Dismantled and/or in storage. L -  Severe loss of historic integrity due to alteration.

Divider

Back

Top

Divider