Bridge Type
Main Span(s): Concrete [1] Box beam or girders - Multiple [05]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Bituminous [6]
Bridge Dimensions
Length: 23.8 m = 78.1 ft
Main Spans: 1 at 21.3 m = 69.9 ft
Approach Spans: 0
Skew: 6
Width, Roadway: 10.4 m = 34.1 ft (2 Lanes) and Out-To-Out: 13 m = 42.7 ft for a 10.4 m = 34.1 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Los Angeles [44000]: Los Angeles County [037], California [06]
Owned by City or Municipal Highway Agency [04], DOT District: 7
0.1 MI E COLDWTER CYN AVE
Condition
Deck: Good [7]
Superstructure: Good [7]
Substructure: Good [7]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 99.8 metric ton = 109.8 tons (Load Factor(LF) [1])
Inventory: 65.4 metric ton = 71.9 tons (Load Factor(LF) [1])
Appraisal
Structural: Better than present minimum criteria [7]
Deck Geometry: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Road Alignment: Equal to present desirable criteria [8]
Waterway: Superior to present desirable criteria [9] and Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Inspections
Date: November 2020 [1120] and Frequency: 48
Future Work
Work Needed:
Bridge Detour: 0.2 km = 0.1 mi
Traffic
ADT: 19500 (2005) and Trucks: 2%
Future ADT: 23127 (In 2037
)