HistoricBridges.org Menu: HistoricBridges.org Menu:



BridgeSeek

Nearby Bridges in NBI 2021: 1


U.S. 281 over S. CANADIAN RIVER (Route: 281)
Num:40850000000000x
Posted for load [P]
Built: 1933, Reconstructed: N/A [0000]
Historic: Bridge is eligible for the NRHP. [2]

Google Streetview (If Available)

Rough Distance: 0.4 Miles (0.6 Kilometers)

Bridge Type
Main Span(s): Steel [3] Truss - Thru [10]
Approach Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Bituminous [6]
Bridge Dimensions
Length: 1200 m = 3937.2 ft
Main Spans: 38 at 30.5 m = 100.1 ft
Approach Spans: 2
Skew: 0
Width, Roadway: 7.3 m = 24.0 ft (2 Lanes) and Out-To-Out: 7.9 m = 25.9 ft for a 9.1 m = 29.9 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Unknown [00000]: Canadian County [017], Oklahoma [40]
Owned by State Highway Agency [01], DOT District: 4
CADDO CANADIAN CL
Condition
Deck: Poor [4]
Superstructure: Poor [4]
Substructure: Fair [5]
Loading
Design: M 13.5 / H 15 [2]
Operating: 8.3 metric ton = 9.1 tons (Load Factor(LF) [1])
Inventory: 7.3 metric ton = 8.0 tons (Load Factor(LF) [1])
Appraisal
Structural: Basically intolerable requiring high priority of replacement [2]
Deck Geometry: Meets minimum tolerable limits to be left in place as is [4]
Road Alignment: Equal to present minimum criteria [6]
Waterway: Somewhat better than minimum adequacy to tolerate being left in place as is [5] and Countermeasures have been installed to mitigate an existing problem with scour. [7]
Inspections
Date: October 2020 [1020] and Frequency: 12
Future Work
Work Needed: Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Bridge Detour: 1.9 km = 1.2 mi
Traffic
ADT: 1100 (2019) and Trucks: 16%
Future ADT: 1760 (In 2039 )

Special Bridge Conditions Legend: R - Former location of relocated bridge. ! - At risk for demolition or destruction. X - Confirmed demolished or collapsed. S  - Dismantled and/or in storage. L -  Severe loss of historic integrity due to alteration.