HistoricBridges.org Menu: HistoricBridges.org Menu:



BridgeSeek

Nearby Bridges in NBI 2021: 1


US 62B-S 9-Marion over RR:WHITE RIVER (Route: 62)
Num:702x
Open: no restriction [A]
Built: 1930, Reconstructed: 2004
Historic: Bridge is on the NRHP. [1]

Google Streetview (If Available)

Rough Distance: 0.3 Miles (0.5 Kilometers)

Bridge Type
Main Span(s): Concrete [1] Arch - Thru [12]
Approach Span(s): Concrete [1] Tee beam [04]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Monolithic Concrete (concurrently placed with structural deck) [1]
Bridge Dimensions
Length: 550.2 m = 1805.2 ft
Main Spans: 6 at 65.8 m = 215.9 ft
Approach Spans: 12
Skew: 0
Width, Roadway: 7.3 m = 24.0 ft (2 Lanes) and Out-To-Out: 8.5 m = 27.9 ft for a 7.6 m = 24.9 ft approaching roadway.
Vertical Clearance: 7.62 m = 25.0 ft and Navigational Clearance: 0 = N/A
Location
Unknown [14960]: Marion County [089], Arkansas [05]
Owned by State Highway Agency [01], DOT District: 9
.50 MI E OF JCT 412/62
Condition
Deck: Satisfactory [6]
Superstructure: Satisfactory [6]
Substructure: Satisfactory [6]
Loading
Design: M 13.5 / H 15 [2]
Operating: 28.1 metric ton = 30.9 tons (Load Factor(LF) [1])
Inventory: 17.2 metric ton = 18.9 tons (Load Factor(LF) [1])
Appraisal
Structural: Meets minimum tolerable limits to be left in place as is [4]
Deck Geometry: Meets minimum tolerable limits to be left in place as is [4]
Road Alignment: Meets minimum tolerable limits to be left in place as is [4]
Waterway: Equal to present desirable criteria [8] and Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Inspections
Date: November 2020 [1120] and Frequency: 24
Future Work
Work Needed: Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Bridge Detour: 0.5 km = 0.3 mi
Traffic
ADT: 1000 (2018) and Trucks: 6%
Future ADT: 1486 (In 2028 )

Special Bridge Conditions Legend: R - Former location of relocated bridge. ! - At risk for demolition or destruction. X - Confirmed demolished or collapsed. S  - Dismantled and/or in storage. L -  Severe loss of historic integrity due to alteration.

Divider

Back