HistoricBridges.org Menu: HistoricBridges.org Menu:



BridgeSeek

Nearby Bridges in NBI 2021: 1


LEWIS CREEK RD over LEWIS CREEK (Route: 0)
Num: 44C0089x
Open: no restriction [A]
Built: 1930, Reconstructed: 1947
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0 Miles (0 Kilometers)

Bridge Type
Main Span(s): Steel [3] Truss - Thru [10]
Approach Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Deck: Open Grating [3] with Wearing Surface: Bituminous [6]
Bridge Dimensions
Length: 24.1 m = 79.1 ft
Main Spans: 1 at 11.9 m = 39.0 ft
Approach Spans: 2
Skew: 0
Width, Roadway: 4.3 m = 14.1 ft (1 Lanes) and Out-To-Out: 5.1 m = 16.7 ft for a 4.6 m = 15.1 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Unknown [00000]: Monterey County [053], California [06]
Owned by County Highway Agency [02], DOT District: 5
0.25 MI E OF RTE 25
Condition
Deck: Fair [5]
Superstructure: Good [7]
Substructure: Poor [4]
Loading
Design:
Operating: 28.5 metric ton = 31.4 tons (Load Factor(LF) [1])
Inventory: 17.2 metric ton = 18.9 tons (Load Factor(LF) [1])
Appraisal
Structural: Meets minimum tolerable limits to be left in place as is [4]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Meets minimum tolerable limits to be left in place as is [4]
Waterway: Somewhat better than minimum adequacy to tolerate being left in place as is [5] and "Bridge with ""unknown"" foundation that has not been evaluated for scour. [U]"
Inspections
Date: August 1999 [899] and Frequency: 24
Future Work
Work Needed: Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Bridge Detour: 19.9 km = 12.3 mi
Traffic
ADT: 150 (2013) and Trucks: 3%
Future ADT: 316 (In 2041 )

Special Bridge Conditions Legend: R - Former location of relocated bridge. ! - At risk for demolition or destruction. X - Confirmed demolished or collapsed. S  - Dismantled and/or in storage. L -  Severe loss of historic integrity due to alteration.