Bridge Type
Main Span(s): Steel continuous [4] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]
Bridge Dimensions
Length: 771.3 m = 2530.6 ft
Main Spans: 3 at 228.6 m = 750.0 ft
Approach Spans: 8
Skew: 0
Width, Roadway: 19.5 m = 64.0 ft (4 Lanes) and Out-To-Out: 23.1 m = 75.8 ft for a 19.5 m = 64.0 ft approaching roadway.
Vertical Clearance: 5.12 m = 16.8 ft and Navigational Clearance: 23.5 m = 77.1 ft
Location
Belpre [05424]: Washington County [167], Ohio [39]
Owned by State Highway Agency [01], DOT District: 10
.8 MI S. MEMORIAL BRIDGE
Condition
Deck: Fair [5]
Superstructure: Fair [5]
Substructure: Fair [5]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 42.1 metric ton = 46.3 tons (Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading [7])
Inventory: 32.4 metric ton = 35.6 tons (Allowable Stress (AS) rating reported by rating factor (RF) method using MS18 loading [7])
Appraisal
Structural: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck Geometry: Better than present minimum criteria [7]
Road Alignment: Equal to present desirable criteria [8]
Waterway: Superior to present desirable criteria [9] and Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Inspections
Date: August 2020 [0820] and Frequency: 24
Future Work
Work Needed: Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Bridge Detour: 0.5 km = 0.3 mi
Traffic
ADT: 16602 (2015) and Trucks: 6%
Future ADT: 0 (In 2040
)