HistoricBridges.org Menu: HistoricBridges.org Menu:



BridgeSeek

Nearby Bridges in NBI 2021: 1


LOWER BUCK RIDGE R over SHERMAN CREEK (Route: 0)
Num:29746x
Posted for load [P]
Built: 1891, Reconstructed: N/A [0000]
Historic: Historical significance is not determinable at this time. [4]

Google Streetview (If Available)

Rough Distance: 0 Miles (0 Kilometers)

Bridge Type
Main Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Wood or Timber [8] with Wearing Surface: Wood or Timber [7]
Bridge Dimensions
Length: 22.9 m = 75.1 ft
Main Spans: 1 at 20.1 m = 65.9 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 3.9 m = 12.8 ft (1 Lanes) and Out-To-Out: 4 m = 13.1 ft for a 4.3 m = 14.1 ft approaching roadway.
Vertical Clearance: 3.51 m = 11.5 ft and Navigational Clearance: 0 = N/A
Location
Toboyne [76920]: Perry County [099], Pennsylvania [42]
Owned by County Highway Agency [02], DOT District: 8
1 S.GRMNTWN/SHRMN CREEK
Condition
Deck: Good [7]
Superstructure: Satisfactory [6]
Substructure: Satisfactory [6]
Loading
Design: MS 18 / HS 20 [5]
Operating: 33.6 metric ton = 37.0 tons (Load Factor(LF) [1])
Inventory: 20 metric ton = 22.0 tons (Load Factor(LF) [1])
Appraisal
Structural: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck Geometry: Basically intolerable requiring high priority of corrrective action [3]
Road Alignment: Meets minimum tolerable limits to be left in place as is [4]
Waterway: Equal to present minimum criteria [6] and Bridge foundations determined to be stable for assessed or calculated scour conditions; field review indicates action is required. [4]
Inspections
Date: October 1999 [1099] and Frequency: 24
Future Work
Work Needed: Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Bridge Detour: 0.8 km = 0.5 mi
Traffic
ADT: 100 (2019) and Trucks: 0%
Future ADT: 140 (In 2039 )

Special Bridge Conditions Legend: R - Former location of relocated bridge. ! - At risk for demolition or destruction. X - Confirmed demolished or collapsed. S  - Dismantled and/or in storage. L -  Severe loss of historic integrity due to alteration.