Bridge Type
Main Span(s): Concrete [1] Arch - Deck [11]
Approach Span(s): Other [00]
Deck: Not applicable [N] with Wearing Surface: Not applicable (applies only to structures with no deck) [N]
Bridge Dimensions
Length: 26.5 m = 86.9 ft
Main Spans: 1 at 23.2 m = 76.1 ft
Approach Spans: 0
Skew: 10
Width, Roadway: 7.4 m = 24.3 ft (2 Lanes) and Out-To-Out: 10.2 m = 33.5 ft for a 7.3 m = 24.0 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Port Royal [62304]: Juniata County [067], Pennsylvania [42]
Owned by Railroad [27], DOT District: 2
PORT ROYAL BORO
Condition
Deck: Not Applicable [N]
Superstructure: Poor [4]
Substructure: Fair [5]
Loading
Design: M 13.5 / H 15 [2]
Operating: 41.7 metric ton = 45.9 tons ()
Inventory: 32.7 metric ton = 36.0 tons ()
Appraisal
Structural: Meets minimum tolerable limits to be left in place as is [4]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: July 2020 [0720] and Frequency: 24
Future Work
Work Needed: Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Bridge Detour: 1.3 km = 0.8 mi
Traffic
ADT: 5372 (2020) and Trucks: 8%
Future ADT: 7330 (In 2040
)