Bridge Type
Main Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Monolithic Concrete (concurrently placed with structural deck) [1]
Bridge Dimensions
Length: 34.8 m = 114.2 ft
Main Spans: 1 at 34.2 m = 112.2 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 6 m = 19.7 ft (2 Lanes) and Out-To-Out: 6.7 m = 22.0 ft for a 6 m = 19.7 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Thomaston [75730]: Litchfield County [005], Connecticut [09]
Owned by Corps of Engineers (Civil) [70], DOT District: 4
.80 KM E CT RTE. 8
Condition
Deck: Good [7]
Superstructure: Satisfactory [6]
Substructure: Good [7]
Loading
Design: M 13.5 / H 15 [2]
Operating: 99.9 metric ton = 109.9 tons (Allowable Stress(AS) [2])
Inventory: 58.7 metric ton = 64.6 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Equal to present minimum criteria [6]
Deck Geometry: Meets minimum tolerable limits to be left in place as is [4]
Road Alignment: Equal to present desirable criteria [8]
Waterway: Equal to present desirable criteria [8] and Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Inspections
Date: September 2020 [0920] and Frequency: 24
Future Work
Work Needed: Bridge rehabilitation because of general structure deterioration or inadequate strength. [35]
Bridge Detour: 19.9 km = 12.3 mi
Traffic
ADT: 40 (2020) and Trucks: 5%
Future ADT: 40 (In 2040
)