Bridge Type
Main Span(s): Steel [3] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Bituminous [6]
Bridge Dimensions
Length: 52.9 m = 173.6 ft
Main Spans: 1 at 51.8 m = 170.0 ft
Approach Spans: 0
Skew: 20
Width, Roadway: 10.4 m = 34.1 ft (2 Lanes) and Out-To-Out: 13 m = 42.7 ft for a 12 m = 39.4 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Windham [86790]: Windham County [015], Connecticut [09]
Owned by State Highway Agency [01], DOT District: 2
.5 MI EAST JCT 195 & 14
Condition
Deck: Very Good [8]
Superstructure: Very Good [8]
Substructure: Very Good [8]
Loading
Design: M 18 / H 20 [4]
Operating: 43.7 metric ton = 48.1 tons (Load and Resistance Factor Rating (LRFR) rating reported by rating factor (RF) method using HL-93 loadings [8])
Inventory: 33.7 metric ton = 37.1 tons (Load and Resistance Factor Rating (LRFR) rating reported by rating factor (RF) method using HL-93 loadings [8])
Appraisal
Structural: Equal to present desirable criteria [8]
Deck Geometry: Meets minimum tolerable limits to be left in place as is [4]
Road Alignment: Equal to present desirable criteria [8]
Waterway: Superior to present desirable criteria [9] and Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Inspections
Date: May 2020 [0520] and Frequency: 24
Future Work
Work Needed: Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Bridge Detour: 0.6 km = 0.4 mi
Traffic
ADT: 7957 (2018) and Trucks: 6%
Future ADT: 11823 (In 2038
)