HistoricBridges.org Menu: HistoricBridges.org Menu:



BridgeSeek

Nearby Bridges in NBI 2021: 2


RTE 414 over Pedestrian Sidewalk: CHE (Route: 414)
Num:1218080x
Open: no restriction [A]
Built: 1979, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.1 Miles (0.1 Kilometers)

Bridge Type
Main Span(s): Steel continuous [4] Stringer/Multi-beam or girder [02]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Epoxy Overlay [5]
Bridge Dimensions
Length: 297.8 m = 977.1 ft
Main Spans: 5 at 65.8 m = 215.9 ft
Approach Spans: 0
Skew: 34
Width, Roadway: 17.1 m = 56.1 ft (4 Lanes) and Out-To-Out: 22.7 m = 74.5 ft for a 17.1 m = 56.1 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Corning [18256]: Steuben County [101], New York [36]
Owned by State Highway Agency [01], DOT District: 64
IN CORNING
Condition
Deck: Satisfactory [6]
Superstructure: Fair [5]
Substructure: Good [7]
Loading
Design: MS 18 / HS 20 [5]
Operating: 51.5 metric ton = 56.7 tons (Load and Resistance Factor Rating (LRFR) rating reported by rating factor (RF) method using HL-93 loadings [8])
Inventory: 39.9 metric ton = 43.9 tons (Load and Resistance Factor Rating (LRFR) rating reported by rating factor (RF) method using HL-93 loadings [8])
Appraisal
Structural: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck Geometry: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Road Alignment: Equal to present desirable criteria [8]
Waterway: Equal to present desirable criteria [8] and Bridge foundations determined to be stable for assessed or calculated scour condition. [5]
Inspections
Date: August 2020 [0820] and Frequency: 24
Future Work
Work Needed: Widening of existing bridge with deck rehabilitation or replacement. [34]
Bridge Detour: 1.2 km = 0.7 mi
Traffic
ADT: 12045 (2017) and Trucks: 5%
Future ADT: 14632 (In 2039 )
BRIDGE STREET over CHEMUNG RIVER (Route: 0)
Num:2218090x
Posted for other load-capacity restriction [R]
Built: 1937, Reconstructed: 2019
Historic: Historical significance is not determinable at this time. [4]

Google Streetview (If Available)

Rough Distance: 0.5 Miles (0.8 Kilometers)

Bridge Type
Main Span(s): Steel continuous [4] Truss - Thru [10]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]
Bridge Dimensions
Length: 178 m = 584.0 ft
Main Spans: 3 at 67.9 m = 222.8 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 11.4 m = 37.4 ft (2 Lanes) and Out-To-Out: 13.1 m = 43.0 ft for a 11.3 m = 37.1 ft approaching roadway.
Vertical Clearance: 4.57 m = 15.0 ft and Navigational Clearance: 0 = N/A
Location
Corning [18256]: Steuben County [101], New York [36]
Owned by City or Municipal Highway Agency [04], DOT District: 64
IN CORNING
Condition
Deck: Good [7]
Superstructure: Fair [5]
Substructure: Satisfactory [6]
Loading
Design: MS 18 / HS 20 [5]
Operating: 56.2 metric ton = 61.8 tons (Load Factor(LF) [1])
Inventory: 33.6 metric ton = 37.0 tons (Load Factor(LF) [1])
Appraisal
Structural: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck Geometry: Meets minimum tolerable limits to be left in place as is [4]
Road Alignment: Equal to present minimum criteria [6]
Waterway: Equal to present desirable criteria [8] and Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Inspections
Date: December 1999 [1299] and Frequency: 24
Future Work
Work Needed: Widening of existing bridge with deck rehabilitation or replacement. [34]
Bridge Detour: 0.1 km = 0.1 mi
Traffic
ADT: 8639 (2017) and Trucks: 2%
Future ADT: 10689 (In 2039 )

Special Bridge Conditions Legend: R - Former location of relocated bridge. ! - At risk for demolition or destruction. X - Confirmed demolished or collapsed. S  - Dismantled and/or in storage. L -  Severe loss of historic integrity due to alteration.

Divider

Back

Top

Divider

About - Contact

Divider