HistoricBridges.org Menu: HistoricBridges.org Menu:



BridgeSeek

Nearby Bridges in NBI 2021: 1


CTH K over YELLOW RIVER (Route: 0)
Num:B09049700000000x
Posted for load [P]
Built: 1942, Reconstructed: 1985
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0 Miles (0 Kilometers)

Bridge Type
Main Span(s): Steel [3] Truss - Thru [10]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Monolithic Concrete (concurrently placed with structural deck) [1]
Bridge Dimensions
Length: 47.1 m = 154.5 ft
Main Spans: 1 at 45.7 m = 149.9 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 7.3 m = 24.0 ft (2 Lanes) and Out-To-Out: 7.6 m = 24.9 ft for a 7.9 m = 25.9 ft approaching roadway.
Vertical Clearance: 4.15 m = 13.6 ft and Navigational Clearance: 0 = N/A
Location
Anson [02175]: Chippewa County [017], Wisconsin [55]
Owned by County Highway Agency [02], DOT District: 6
0.5 M NW 72ND AVENUE
Condition
Deck: Good [7]
Superstructure: Fair [5]
Substructure: Satisfactory [6]
Loading
Design: MS 18 / HS 20 [5]
Operating: 50.6 metric ton = 55.7 tons (Load Factor(LF) [1])
Inventory: 34 metric ton = 37.4 tons (Load Factor(LF) [1])
Appraisal
Structural: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Equal to present minimum criteria [6]
Waterway: Equal to present desirable criteria [8] and Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Inspections
Date: August 2020 [0820] and Frequency: 24
Future Work
Work Needed: Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Bridge Detour: 2.8 km = 1.7 mi
Traffic
ADT: 1908 (2018) and Trucks: 0%
Future ADT: 2098 (In 2039 )

Special Bridge Conditions Legend: R - Former location of relocated bridge. ! - At risk for demolition or destruction. X - Confirmed demolished or collapsed. S  - Dismantled and/or in storage. L -  Severe loss of historic integrity due to alteration.