Nearby Bridges in NBI 2021: 1


I-64 over CONRAIL: NW-ERN PKWY (Route: 64)
Num:056B00285Nx
Posted for load [P]
Built: 1972, Reconstructed: N/A [0000]
Historic: Bridge is not eligible for the NRHP. [5]

Google Streetview (If Available)

Rough Distance: 0.5 Miles (0.8 Kilometers)

Bridge Type
Main Span(s): Steel continuous [4] Girder and floorbeam system [03]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Bituminous [6]
Bridge Dimensions
Length: 645 m = 2116.2 ft
Main Spans: 22 at 53.3 m = 174.9 ft
Approach Spans: 0
Skew: 99
Width, Roadway: 27 m = 88.6 ft (6 Lanes) and Out-To-Out: 28.7 m = 94.2 ft for a 27 m = 88.6 ft approaching roadway.
Vertical Clearance: 99.99 m = 328.1 ft and Navigational Clearance: 0 = N/A
Location
Unknown [00000]: Jefferson County [111], Kentucky [21]
Owned by State Highway Agency [01], DOT District: 5
0.75 MI E OF US 150 NTRCH
Condition
Deck: Satisfactory [6]
Superstructure: Fair [5]
Substructure: Fair [5]
Loading
Design: MS 18+Mod / HS 20+Mod [6]
Operating: 21.7 metric ton = 23.9 tons (Load and Resistance Factor Rating (LRFR) rating reported by rating factor (RF) method using HL-93 loadings [8])
Inventory: 16.5 metric ton = 18.2 tons (Load and Resistance Factor Rating (LRFR) rating reported by rating factor (RF) method using HL-93 loadings [8])
Appraisal
Structural: Meets minimum tolerable limits to be left in place as is [4]
Deck Geometry: Somewhat better than minimum adequacy to tolerate being left in place as is [5]
Road Alignment: Equal to present desirable criteria [8]
Waterway: N/A [N] and Bridge not over waterway. [N]
Inspections
Date: July 1999 [799] and Frequency: 24
Future Work
Work Needed: Widening of existing bridge with deck rehabilitation or replacement. [34]
Bridge Detour: 0.6 km = 0.4 mi
Traffic
ADT: 72032 (2018) and Trucks: 9%
Future ADT: 79235 (In 2038 )