HistoricBridges.org Menu: HistoricBridges.org Menu:



BridgeSeek

Nearby Bridges in NBI 2021: 1


COOMBS BRIDGE RD over ASHUELOT RIVER (Route: 0)
Num:27901430017500x
Posted for load [P]
Built: 1837, Reconstructed: 1997
Historic: Bridge is possibly eligible for the NRHP. [3]

Google Streetview (If Available)

Rough Distance: 0 Miles (0 Kilometers)

Bridge Type
Main Span(s): Wood or timber [7] Truss - Thru [10]
Approach Span(s): Other [00]
Deck: Wood or Timber [8] with Wearing Surface: Wood or Timber [7]
Bridge Dimensions
Length: 36.6 m = 120.1 ft
Main Spans: 1 at 34.1 m = 111.9 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 4.3 m = 14.1 ft (1 Lanes) and Out-To-Out: 5 m = 16.4 ft for a 5.5 m = 18.0 ft approaching roadway.
Vertical Clearance: 2.59 m = 8.5 ft and Navigational Clearance: 0 = N/A
Location
Winchester [85540]: Cheshire County [005], New Hampshire [33]
Owned by City or Municipal Highway Agency [04], DOT District: 4
0.27MI. NH119
Condition
Deck: Satisfactory [6]
Superstructure: Satisfactory [6]
Substructure: Good [7]
Loading
Design:
Operating: 12.4 metric ton = 13.6 tons (Allowable Stress(AS) [2])
Inventory: 9.8 metric ton = 10.8 tons (Allowable Stress(AS) [2])
Appraisal
Structural: Basically intolerable requiring high priority of replacement [2]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Basically intolerable requiring high priority of replacement [2]
Waterway: Better than present minimum criteria [7] and Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Inspections
Date: August 2020 [0820] and Frequency: 24
Future Work
Work Needed: Replacement of bridge or other structure because of substandard load carrying capacity or substantial bridge roadway geometry. [31]
Bridge Detour: 0.5 km = 0.3 mi
Traffic
ADT: 676 (2019) and Trucks: 4%
Future ADT: 1000 (In 2041 )

Special Bridge Conditions Legend: R - Former location of relocated bridge. ! - At risk for demolition or destruction. X - Confirmed demolished or collapsed. S  - Dismantled and/or in storage. L -  Severe loss of historic integrity due to alteration.

Divider

Back

Top

Divider

About - Contact

Divider