HistoricBridges.org Menu: HistoricBridges.org Menu:



BridgeSeek

Nearby Bridges in NBI 2021: 1


QUAKER ROAD over ERIE CANAL (Route: 0)
Num:4437210x
Open: no restriction [A]
Built: 1914, Reconstructed: N/A [0000]
Historic: Historical significance is not determinable at this time. [4]

Google Streetview (If Available)

Rough Distance: 0 Miles (0 Kilometers)

Bridge Type
Main Span(s): Steel [3] Truss - Thru [10]
Approach Span(s): Other [00]
Deck: Concrete Cast-in-Place [1] with Wearing Surface: Integral Concrete (separate non-modified layer of concrete added to structural deck) [2]
Bridge Dimensions
Length: 51.5 m = 169.0 ft
Main Spans: 1 at 50.2 m = 164.7 ft
Approach Spans: 0
Skew: 0
Width, Roadway: 4.5 m = 14.8 ft (1 Lanes) and Out-To-Out: 5 m = 16.4 ft for a 4.6 m = 15.1 ft approaching roadway.
Vertical Clearance: 4.62 m = 15.2 ft and Navigational Clearance: 4.8 m = 15.7 ft
Location
Macedon [44160]: Wayne County [117], New York [36]
Owned by State Highway Agency [01], DOT District: 47
0.5 MI SE JCT RTE 31F + C
Condition
Deck: Poor [4]
Superstructure: Serious [3]
Substructure: Satisfactory [6]
Loading
Design: Other [C]
Operating: 21.8 metric ton = 24.0 tons (Load Factor(LF) [1])
Inventory: 12.7 metric ton = 14.0 tons (Load Factor(LF) [1])
Appraisal
Structural: Basically intolerable requiring high priority of corrrective action [3]
Deck Geometry: Basically intolerable requiring high priority of replacement [2]
Road Alignment: Meets minimum tolerable limits to be left in place as is [4]
Waterway: Somewhat better than minimum adequacy to tolerate being left in place as is [5] and Bridge foundations determined to be stable for the assessed or calculated scour condition. [8]
Inspections
Date: June 2020 [0620] and Frequency: 12
Future Work
Work Needed: Bridge deck replacement with only incidental widening. [37]
Bridge Detour: 0.3 km = 0.2 mi
Traffic
ADT: 652 (2017) and Trucks: 2%
Future ADT: 913 (In 2037 )

Special Bridge Conditions Legend: R - Former location of relocated bridge. ! - At risk for demolition or destruction. X - Confirmed demolished or collapsed. S  - Dismantled and/or in storage. L -  Severe loss of historic integrity due to alteration.

Divider

Back

Top

Divider

About - Contact

Divider