View Information About HSR Ratings
Today, this is one of the last surviving examples of a state standard truss bridge in northwestern Indiana. It has two 60 foot continuous stringer spans at the northern end.
This bridge provides a striking example of the potential problems created when real rivets are avoided during historic bridge rehabilitation. Rather than replacing deteriorated rivets with new hot-driven rivets, conventional bolts were installed and covered with plastic caps intended to imitate the appearance of traditional round rivet heads.
The photographs show that this cosmetic treatment can create a serious maintenance problem. Moisture can enter around the plastic cap and become trapped against the steel fastener, allowing corrosion to develop largely hidden from inspection. In several locations, corrosion products have expanded enough to split the plastic caps apart, exposing heavily deteriorated bolts beneath them.
The irony is that many of the bridge's original rivets, which the replacement system was intended to imitate, have survived approximately a century of service. This bridge demonstrates why actual structural riveting should remain a serious option for historic truss rehabilitation. A properly driven rivet provides both the historically correct appearance and the structural fastener itself, without adding a moisture-trapping cosmetic shell over the connection.
Attempts to avoid traditional riveting may therefore produce a repair that is not only less authentic, but potentially less durable than simply installing new rivets.
Information and Findings From DHPA Historic Bridge SurveyBridge History and Significance L & K Contracting Company, Inc. of Terre Haute, Indiana, won a $65,981.52 contract in March 1941 to build this three-span structure of state design upon concrete piers and abutments. The plan called for a pair of continuous 60-ft. I-beam spans to the North and a long Parker through- truss span over the river. The new structure was probably completed either near the end of 1941 or in early 1942. The ISHC had developed standard plan #1521 for a 200-ft. span with a 26-ft. roadway sandwiched between a pair of 2-ft. walks. Truss depth varied from 24 ft. at the portal to 39 ft. at midspan. Each truss carried nine panels, the outer two on each end at 20 ft. 7.5 in. and the inner five at 23 ft. 6 in. Every top chord member is differently sloped; only the central panel's one is parallel with the lower chord; and all were fabricated from a pair of 15-in. channels (@45# for the endposts, third, fourth, and fifth panels, and @40# for the second). For the lower chord, a pair of 15-in. channels riveted together with battens grow in weight from the outer panels (@40#) to the inner-most one (@55#). The state used rolled I-beams in a few web members. The verticals or posts consist of two forms and weights: the hip vertical is a 10-in. I-beam (@33#); the others are made from a pair of laced 10-in. channels (@15.3#). To protect the quite-tall trusses against wind and vehicle-induced stress, substantial latticed struts and heavy upper sway framing buttress the verticals above 15 ft. of roadway clearance. The portals used latticed sections, too. While a 10-in. I-beam (@41#) provided the second-panel diagonal, the third used a pair of laced 10-in. channels (@20#), the fourth a pair of 12-in. channels (@23.7#), and the fifth a 10-in. I-beam (@21#). Only the central panel was countered. The ISHC prescribed 30-in. I floor-beams increasing in weight toward midspan (@172#>200#) riveted to the verticals above the lower chord. Eight rows of rolled I-beam stringers attached to the floor-beams' sides varied in depth and weight by placement. The 20-ft. panels used 16-in. Is at 36 lbs. for the outside and 18-in. ones at 55 lbs. for the central ones. The 23-ft. 6-in. panels relied on 16-in. outer Is at 37 lbs and 21-in. Is at 29 lbs for the inner ones. Together, the floor-beams and the stringers carry the concrete deck. Angles supply each lower sway-bracing member. Tube-channel-and-post rails lined the inner sides of the trusses, and coped concrete approach rails with bush-hammered panels funneled traffic into the spans. This bridge illustrates the state's longest standard trussed span. The trusses retain their original members, including the metal guardrails. The concrete work has all been replaced. The approach rails are all gone. The new concrete deck widened the roadway by eliminating the walks. References Indiana State Highway Commission, Structure #49-C-1938; Contract #2126; Superstructure Standard #1521. Bridge Considered Historic By Survey: Yes |
![]()
![]()
![]()
Coordinates (Latitude, Longitude):
Search For Additional Bridge Listings:
Bridgehunter.com: View listed bridges within 0.5 miles (0.8 kilometers) of this bridge.
Bridgehunter.com: View listed bridges within 10 miles (16 kilometers) of this bridge.
Additional Maps:
Google Streetview (If Available)
GeoHack (Additional Links and Coordinates)
Apple Maps (Via DuckDuckGo Search)
Apple Maps (Apple devices only)
Android: Open Location In Your Map or GPS App
Flickr Gallery (Find Nearby Photos)
Wikimedia Commons (Find Nearby Photos)
Directions Via Sygic For Android
Directions Via Sygic For iOS and Android Dolphin Browser
USGS National Map (United States Only)
Historical USGS Topo Maps (United States Only)
Historic Aerials (United States Only)
CalTopo Maps (United States Only)
© Copyright 2003-2026, HistoricBridges.org. All Rights Reserved. Disclaimer: HistoricBridges.org is a volunteer group of private citizens. HistoricBridges.org is NOT a government agency, does not represent or work with any governmental agencies, nor is it in any way associated with any government agency or any non-profit organization. While we strive for accuracy in our factual content, HistoricBridges.org offers no guarantee of accuracy. Information is provided "as is" without warranty of any kind, either expressed or implied. Information could include technical inaccuracies or errors of omission. Opinions and commentary are the opinions of the respective HistoricBridges.org member who made them and do not necessarily represent the views of anyone else, including any outside photographers whose images may appear on the page in which the commentary appears. HistoricBridges.org does not bear any responsibility for any consequences resulting from the use of this or any other HistoricBridges.org information. Owners and users of bridges have the responsibility of correctly following all applicable laws, rules, and regulations, regardless of any HistoricBridges.org information.
![]()